Power Amplifier FA400

|
| Number of Channels |
2 |
| Max. Output Power @ 1 kHz Test Mode |
110 W @ 8 Ohm per channel
160 W @ 4 Ohm per channel
400 W @ 4 Ohm bridged |
| Max. Output Power @ 1 kHz Continuous Mode |
10 W @ 8 Ohm per channel
20 W @ 4 Ohm per channel |
| Max Output Voltage |
30 Vrms @ 8 Ohm load |
|
Frequency Range
|
5 Hz - 30 kHz |
| Gain |
6 dB fixed |
| THD |
0,05 % @ 20 Hz - 20 kHz, 1 Watt
0,03 % @ 1 kHz, - 1 dB under clip |
| Hum and Noise |
<-105 dB |
| Input Impedance |
20 kOhm |
| Output Impedance |
30 mOhm |
| Input Connector |
Combo XLR with 1/4” jack, balanced |
|
Output Connector
|
Speakon 4-pole
Bridged mono outputs in one Speakon connector |
| Cooling |
Convection type |
|
Protections
|
Thermal protection, protect indicator, clip Indicator |
| Signal Indication |
LED for Signal present, -25 dB below full output |
|
Power Supply
|
230 V or 115 V by manual voltage selector |
| Dimensions W x H x D |
483 x 44 x 280 mm (19” x 1.75” x 11”)
19” rack mount, 1 rack unit high (1U) |
|
Temperature
|
Operation +5° to +40°C (+41° to +104°F)
Storage -25° to +70°C (13° to +158°F) |
| Humidity |
< 90% RH (non-condensing at 40°C (104°F)) |
|
Weight
|
7.5 kg, 17 lbs |
| Approvals |
CE Emission EN 55 103-1, E3
C-Tick mark for Australia and New Zealand
Immunity EN 55 103-2, E3
Safety EN 60 065, class I |
|
| |
|
|
|
|
|
|
|