| Measurements |
Level-RMS, Level-SPL, Level-LEQ, Level-Relative, THD+N, vu+PPM, Polarity Test, Signal Balance Error, Frequency Sweep, Time Sweep, 1/3rd Octave Spectrum, ScopeFrequency, AFILS measurements (with MiniLINK) |
| Level |
| Units dBu, dBV, VRMS |
|
Accuracy ± 0.5 % @ 1 kHz |
| Flatness ± 0.1 dB |
|
Bandwidth 20 Hz to 20 kHz |
| Resolution 3 digits (dB-scale) or 4 digits (V-scale) | |
| Frequency |
| Range: |
|
10 Hz to 20 kHz |
| Resolution: |
|
4 digits |
| Accuracy: |
|
< ± 0.1 % | |
| THD+N |
| including 2nd to 5th harmonics analysis |
|
Meas. Bandwidth: |
|
10 Hz to 20 kHz |
| Resolution: |
|
4 digits |
| Residual THD+N: |
|
balanced < -85 dB @ -10 dBu to +20 dBu |
|
|
unbalanced < -74 dB @ 0 dBu to +14 dBu | |
| vu + PPM |
vu-Indicator and Peak Program Meter According to IEC 60268 and DIN 45406, PPM Type I, IIa and Nordic. Both meters with adjustable reference and with analog & numerical peak-hold readout. |
| Polarity Test |
Positive / Negative detection through internal microphone or XLR/RCA connector. Checks polarity of tweeters, midrange-speakers, woofers, sub-woofers and cables. Down to 10 dB S/N ratio of input signal. MR2 or MR-PRO provides the test signal. |
| Balance Error |
Indication range 0.0 % to 100 % Deviation from perfect balance in % or *1 |
| Sweep |
Frequency Sweep: Level as function of frequency. Time Sweep: Measurement of level, THD+N and frequency as function of time. |
| 1/3rdOctave |
Spectrum acc. IEC 1260, class II and ANSI S1.11-1976, class II from 50 Hz to 20 kHz, Bargraph for LevelRMS 20 Hz to 20 kHz |
| Scope |
Auto triggering, auto ranging, auto scaling |
| Filters |
Linear, A-weighting, C-weigting, C-message, Highpass 22 Hz / 60 Hz / 400 Hz, X-Curve-1, Voice bandpass |
| Input Connectors |
XLR balanced, RCA unbalanced |
| Impedance |
40 kOhm balanced, 20 kOhm unbalanced |
| Max. AC Input |
balanced +20 dBu (7.75 VRMS), unbalanced +14 dBu (3.8 VRMS) for input levels > 20 dBu (balanced) the Adapter -20 dB is available as accessory |
| Max. DC Input |
± 50 VDC |
| Residual Noise |
< 12 µV, XLR-input shorted |
| Internal Mic |
Omni directional (for polarity and delay measurement only) |
| Monitor Output |
Jack 3.5 mm (1/8“), suitable for all common headsets |
| Display |
Graphic LCD 64 x 100 pixel, with backlight |
| Batteries |
3x AA batteries (alkaline) Typical battery lifetime > 16 |
| Dimensions |
163 x 86 x 42 mm (6.4“ x 3.38“ x 1.63“) |
| Weight |
300 g (10.5 oz) incl. batteries |
| Temperature |
0° to +45° C (32° to 113° F) |
| Humidity |
90 % R.H., non condensing |