Stereo Appliance Testing
The sequencer capability of RT-Speaker supports sequential testing of multiple inputs to either electrical or acoustical outputs in any combination. Such a set-up verifies multiple input channels of the DUT (Line, Aux, Microphone,...) in combination with the direct acoustical behaviour (Left+Right speakers) of the device.
Additional microphones or vibration sensors may probe for housing vibrations or loose grids. One or more Input- and Output Switchers may be integrated for comprehensive matrix testing. System Requirements:
 |
RT-2M Audio Analyzer |
 |
PureSoundTM incl. RT-Speaker Test Software |
 |
M2010 Measurement Microphone (2x) |
 |
RT-OS Output Switcher |
|
optional: |
 |
Environmental Sensor | |

|
100V Speaker Testing
The PureSound speaker test system allows impedance response- & resonance frequency testing of 100 Volt speakers, which are often used in public address systems. Lower speaker test voltages, such as 75V, 50V, 25V are also supported.
In the past the speaker and the 100V transformer had to be tested seperately as individual components. The complete assembly could not be tested. Assembling faults often have been detected at the actual speaker installation on-site only.
Now NTI offers the all-in-one solution testing the complete assembled 100V speaker with transformer within typ. 3 seconds. The Impendance Box RT-IB 100V enables impedance measurements up to 30 kohm, allowing to test all power-taps of a 100V speaker transformer.
System Requirements:
 |
RT-2M Audio Analyzer |
 |
PureSoundTM incl. RT-Speaker Test Software |
 |
M2010 Measurement Microphone (2x) |
 |
RT-IB 100V Impedance Box |
|
optional: |
 |
Environmental Sensor | |

|