Handheld Solution for Occupational Health
|

|
Applications:
- Measure noise exposure at work according directive 2003/10/EC
- Confirm compliance with health standards ISO 1999:1990
- Prevent hearing loss at work
download pdf
|
|
Advantages
|

XL2 Audio and Acoustic Analyzer
with M2210 Measurement Microphone
|
- Handheld and compact design for field applications
- Calibrated acoustic measurement system
- Improved efficiency with dedicated measurements profiles and appending test results to previous data records
- Automated sound level documentation and high resolution wav-file recording in 24 Bit / 48 kHz format to SD Card
|
|
|
- Sound pressure level SPL
for industrial sound pollution monitoring
- LAeq (averaged sound level with A-weighting)
- LCpeak (peak sound level with C-weighting)
- Stack Light
Alarms at exceeding sound levels, thus employees near the test station are notified immediately.
- Noise exposure level LEX,8h
The Noise at Work Directive 2003/10/EC reduces the risk of hearing damage for employees. The action limits are
|
|
LEX,8h
|
LCpeak
|
Action
|
|
Lower limit value
|
80 dB(A)
|
135 dB
|
recommend wearing hearing protectors
|
|
Upper limit value
|
85 dB(A)
|
137 dB
|
hearing protectors must be worn and noise level reduced as possible
|
|
Exposure limit
|
87 dB(A)
|
140 dB
|
employee with hearing protectors shall never exceed this limits
|
|
Determination of Noise Exposure Level LEX,8h
|
Screenshot Sound Level Meter
|
- At steady noise (applies for LAS deviation is < 5 dB)
Measure the LAeq over a few minutes, the resulting LAeq represents the noise exposure level of the complete 8 hours period LEX,8h = LAeq. The following formula applies for a daily exposure time ≠ 8 hours:
LEX,8h = LAeq + 10 x log ( T / 8 hours )
- At steady noise with stepwise level variations
(applies for steady noise at clearly distinguishable levels)
Measure the LAeq at the different levels and note the corresponding exposure time. Enter all data in the NTi Audio noise exposure level post processing form; the LEX,8h will be calculated and displayed.
Download "Noise exposure level post processing form" here
- At varying noise levels
LEX,8h = LAeq measured for 8 hours.
|
Order Information
|
Exel Occupational Health Set
|
|
Description
|
NTi Audio #
|
| Exel Acoustic Set Class 2 with M4260 Measurement Microphone |
600 000 400
|
| Exel Acoustic Set Class 1 frequency response with M2210 Measurement Microphone |
600 000 410
|
| Stack Light |
600 000 381/382
|
|
|
| |
|
|
|
|
|
|
|