Products
|
Solutions
|
Service
|
Contacts
|
About NTi Audio
|
Press
Your browser does not support inline frames
en
|
de
|
cn
|
jp
Navigation:
Home
-
Solutions
-
Production Test Solutions
-
Microphone
-
Specifications
Solutions
Handheld Solutions
Production Test Solutions
Speaker/Transducer
Microphone
Applications
Accessories
Downloads
Specifications
Mobile Phone
Pro/Consumer Audio
POTS Interfaces
Measurements
Microphone Testing
The NTi Audio microphone test system is a comprehensive test solution with short test cycle times. The turnkey system is based on the high-speed audio analyzer RT-2M and the dedicated production test software "RT-Microphone". It provides a comprehensive set of measurements for the total quality control of microphone components or final assembled products, such as mobile phones, vocal microphones, headsets or MEMS microphones.
Schematic Setup:
> Description <
> Applications <
> Accessories <
> Downloads <
> Specifications <
Specifications
Specifications PureSound Test System (Abstract)
Stepped Sweep
Generator
•
2 Independent Channels
•
Frequency Resolution 1 – 500 steps
•
Frequency Range 20 Hz – 20 kHz
•
Level Range -63 dBV to +26 dBV in 0.1 dB steps
•
Level Accuracy < ±0.1 dB @ 1 kHz
Sweep/Chirp
Generator
•
2 Independent Channels
•
Frequency Range 5 Hz – 6 kHz
•
Level Range -63 dBV to +26 dBV in 0.1 dB steps
•
Level Accuracy < ±0.1 dB @ 1 kHz
Analyzer
•
2 Independent Channels
•
Frequency Range 20 Hz – 20 kHz
•
Level Range –60 to +40 dBVp (0.1 mVp to 100 Vp)
•
Level Accuracy < ±0.1 dB @ 1 kHz
•
Residual Distortion< -86 dB @ level > -20 dBV
•
Residual Noise < -100 dBV
•
Residual Input Idle Channel Noise < -18 dBrnc
•
Phase Accuracy (A-B) ±1 deg
•
Residual Interchannel Crosstalk typ. < -80dB @ level > -20 dBV
•
Selectable Input Impedance per Channel 100 kohm, 600 ohm
•
Phantom Power 15/48 VDC
General
•
Dimensions 1 rack unit high 483 x 318 x 44 mm (19“ x 12.5“ x 1.75“)
•
Weight 7 kg (15 lbs.)
•
Control InterfacesGPIB (IEEE-488.2), RS232
•
Mains Power 100 - 230VAC / 50 - 60 Hz
•
Calibration interval 1 year recommended
•
Operating Temperature+5 to +45 °C (+40 to +110 F)
•
Relative Humidity< 90 % non condensing
Functions
•
Frequency Response
•
Distortion (THD, 2. - 5. harmonics))
•
Impedance Response
•
Resonance Frequencies f0
•
Sound Pressure Level dBSPL
•
Speaker Polarity
•
Rub&Buzz defects analysis with a 100% correlation to the human ear
•
Thiele/Small Parameters
•
DC Resistance
Copyright 2010 by NTi Audio
|
Terms Of Use
|
Privacy Statement
|
Register
|