Microphone Testing
|

|
The NTi Audio microphone test system is a comprehensive test solution with short test cycle times. The turnkey system is based on the high-speed FX100 Audio Analyzer and the dedicated production test software "RT-Microphone". It provides a comprehensive set of measurements for the total quality control of microphone components or final assembled products, such as mobile phones, vocal microphones, headsets or MEMS microphones.
Schematic Setup:

|
|
Analog Generator
| Test Signals |
Sinusoidal, StepSweep, GlideSweep, White Noise
|
| Level Range |
10 μV to 12.45 V (–100 dBV to +21.9 dBV)
|
| Level Accuracy |
±0.04 dB @ 1 kHz (balanced, output load > 2 kΩ) |
|
Level Flatness
|
≤ ±0.01 dB @ (–80 dBV to +21.9 dBV), (10 Hz to 20 kHz)
|
|
Frequency Range
|
5 Hz to 80 kHz |
| Residual THD+N |
| • |
–104 dB @ 1 kHz, 0 dBV (typical) |
| • |
≤ (–101 dB + 0.8 μV) @ BW 22 kHz |
|
Analog Analyzer
Measurement
Functions |
| • |
Frequency |
| • |
Level (selective and wideband) |
| • |
FFT |
| • |
Gain
|
| • |
THD |
| • |
THD+N |
| • |
Harmonic Distortions k2-k35 |
| • |
Crosstalk |
| • |
Phase |
| • |
DC-Level |
| • |
DC-Impedance |
| • |
PureSound™ Rub&BuzzDetection (optional)
|
|
| Sweeps |
| • |
StepSweep: Frequency Sweep, Time Sweep, Level Sweep, Table Sweep |
| • |
GlideSweep: Frequency Sweep |
|
| GlideSweep Speed |
Down to 100 ms for frequency response (20 Hz to 20 kHz)
|
| Level Range |
< 1.0 μV to 141 V (max 200 Vp), channel independent auto ranging |
| Level Accuracy |
±0.04 dB @ 1 kHz |
| Level Flatness |
< ±0.015 dB (20 Hz to 20 kHz) |
| Frequency Range |
DC, 5 Hz to 80 kHz |
| Residual THD+N |
| • |
≤ (–104 dB + 0.5 μV) @ 22 kHz BW |
| • |
–108 dB @ 1 kHz, 0 dBV (typical) |
|
| Residual Noise |
≤ 1.7 μV (20 Hz to 20 kHz bandwidth) |
| Filters |
| • |
A-weighting, C-message
|
| • |
Lowpass: 3.4 kHz, 8 kHz, 15 kHz, 20 kHz Brickwall (AES 17), 22.4 kHz, 40 kHz
|
| • |
Highpass: 10 Hz, 22.4 Hz, 100 Hz, 300 Hz, 400 Hz |
|
| Residual XTalk |
≤ (–125 dB + 1 μV) @ 10 Hz to 20 kHz |
| Input Bias Supply |
2 VDC or 48 VDC Phantom Power, ICP®
DCR measurement current 100 μA or 1.6 mA |
| Input Coupling |
DC or AC (< 3 Hz) |
General
| Channels |
| • |
2 or 4 Parallel Independent Inputs/Outputs Analog |
| • |
XLR and BNC connectors, Binding post
|
|
| Extension Slots |
3 empty slots @ Base Unit FX100 for modular extensions |
| Interfaces |
| • |
USB 2.0 Communication to PC |
| • |
Headphone connector for audio out, 1/4”Jack Stereo |
| • |
LAN (prepared for later firmware extension) |
|
| Pass/Fail Result |
| • |
Built in DIO-Interface controls external peripherals |
| • |
Dual color display with green/red indication |
|
| FX-Control Suite |
| • |
PC Software with full access to all audio analyzer features |
| • |
Parallel measurements with internal/external triggering |
| • |
Calculation panels for mathematical processing of measurement data |
| • |
Result reporting: txt-files, csv-files or xlsx-files |
| • |
Full tolerance handling and hardware wiring diagram |
|
| Programming |
Supports .NET Assembly (e.g. C#.NET, Visual Basic.NET) |
| Design |
Desktop use or ½ size 19’’ rack mounting |
| Mains Power |
100 - 230VAC / 50 - 60 Hz |
| Calibration interval |
1 year recommended |
| Dimensions |
W x H x D: 215 x 132 x 429 mm (8.5" x 5.25" x 16.9"), 3 rack units high |
| Weight |
Base unit 5.12 kg, 11.3 lbs |
| Operating Temperature |
+5°C to +45 °C (+41°F to +113°F) |
| Relative Humidity |
< 90 % non condensing |
All information is subject to change without notice.
FLEXUS, FX100, FX-Control and PureSound are trademarks of NTi Audio.
ICP® is a registered trademark of PCB Piezotronics.
|
| |
|
|
|
|
|
|
|
| Login |
|