{"id":8618,"date":"2024-11-27T03:17:00","date_gmt":"2024-11-27T02:17:00","guid":{"rendered":"https:\/\/www.nti-audio.com\/mise-a-jour-du-firmware-v1-42-de-lanalyseur-acoustique-xl3"},"modified":"2026-02-03T09:53:03","modified_gmt":"2026-02-03T08:53:03","slug":"mise-a-jour-du-firmware-v1-42-de-lanalyseur-acoustique-xl3","status":"publish","type":"post","link":"https:\/\/www.nti-audio.com\/fr\/societe\/actualites\/mise-a-jour-du-firmware-v1-42-de-lanalyseur-acoustique-xl3","title":{"rendered":"Mise \u00e0 jour du firmware V1.42 de l&#8217;Analyseur Acoustique XL3"},"content":{"rendered":"\n<figure class=\"wp-block-image alignwide size-full\"><img decoding=\"async\" width=\"670\" height=\"325\" src=\"https:\/\/www.nti-audio.com\/wp-content\/uploads\/670350p963EDNmainNTi-Audio-Teaser-Firmware-Update-670x325-1.webp\" alt=\"670350p963ednmainnti Audio Teaser Mise &#xE0; jour du firmware 670x325\" class=\"wp-image-5482\" srcset=\"https:\/\/www.nti-audio.com\/wp-content\/uploads\/670350p963EDNmainNTi-Audio-Teaser-Firmware-Update-670x325-1.webp 670w, https:\/\/www.nti-audio.com\/wp-content\/uploads\/670350p963EDNmainNTi-Audio-Teaser-Firmware-Update-670x325-1-500x243.webp 500w\" sizes=\"(max-width: 670px) 100vw, 670px\" \/><\/figure>\n\n<p><strong>Le firmware V1.42 de l&#8217;Analyseur Acoustique XL3 apporte une interface utilisateur enti\u00e8rement revue qui simplifie consid\u00e9rablement les mesures d&#8217;isolation acoustique.<\/strong> <strong>Tous les niveaux de tiers d&#8217;octave dans les pi\u00e8ces d&#8217;\u00e9mission et de r\u00e9ception sont d\u00e9sormais affich\u00e9s sous forme de graphiques lin\u00e9aires.<\/strong> <strong>Cela permet un enregistrement visuel intuitif du spectre et permet \u00e9galement d&#8217;afficher simultan\u00e9ment plusieurs niveaux et valeurs de r\u00e9f\u00e9rence &#8211; pour des analyses encore plus rapides et plus efficaces.<\/strong><\/p>\n\n<p>Si le niveau de bruit de fond B2 est mesur\u00e9 ou import\u00e9 \u00e0 partir d&#8217;une mesure pr\u00e9c\u00e9dente, ces donn\u00e9es sont directement disponibles pour la mesure du niveau de la pi\u00e8ce de r\u00e9ception L2. Cela permet d&#8217;\u00e9valuer rapidement si un niveau suffisant atteint la pi\u00e8ce de r\u00e9ception depuis la pi\u00e8ce d&#8217;\u00e9mission. Cette analyse peut \u00eatre effectu\u00e9e \u00e0 la fois avec des valeurs \u00ab\u00a0en direct\u00a0\u00bb et avec des valeurs moyenn\u00e9es.  <\/p>\n\n<p>Si une bande L2 est inf\u00e9rieure de 6 dB ou 10 dB \u00e0 la bande B2 correspondante, elle est \u00e9tiquet\u00e9e \u00ab\u00a0b\u00a0\u00bb ou \u00ab\u00a0B\u00a0\u00bb respectivement dans l&#8217;affichage de l&#8217;XL3. Lors de l&#8217;affichage du niveau de la pi\u00e8ce d&#8217;\u00e9mission, les diff\u00e9rences maximales entre les bandes voisines d\u00e9finies dans la norme sont v\u00e9rifi\u00e9es. Si cela est d\u00e9pass\u00e9, il est \u00e9tiquet\u00e9 avec un \u00ab\u00a0A\u00a0\u00bb.  <\/p>\n\n<p>Ces fonctions permettent une \u00e9valuation fiable des conditions de mesure \u00e0 l&#8217;avance et r\u00e9duisent le risque de r\u00e9p\u00e9titions de mesure n\u00e9cessaires, ce qui permet d&#8217;\u00e9conomiser du temps et des efforts.<\/p>\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"480\" height=\"800\" data-id=\"5485\" src=\"https:\/\/www.nti-audio.com\/wp-content\/uploads\/B2_2024-11-17_SLM_0001_screenshot_01.webp\" alt=\"B2 2024 11 17 Slm 0001 Capture d'&#xE9;cran\" class=\"wp-image-5485\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"480\" height=\"800\" data-id=\"5488\" src=\"https:\/\/www.nti-audio.com\/wp-content\/uploads\/L2-2_2024-11-17_SLM_0001_screenshot_02.webp\" alt=\"\" class=\"wp-image-5488\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"480\" height=\"800\" data-id=\"5487\" src=\"https:\/\/www.nti-audio.com\/wp-content\/uploads\/L1-2_2024-11-17_SLM_0001_01_screenshot_03.webp\" alt=\"L1 2 2024 11 17 Slm 0001 01 Capture d'&#xE9;cran\" class=\"wp-image-5487\"\/><\/figure>\n<\/figure>\n\n<p>Le firmware V1.42 permet d&#8217;exclure des mesures individuelles du processus de calcul de la moyenne. Cela peut \u00eatre fait soit directement apr\u00e8s une mesure d\u00e9fectueuse, soit ult\u00e9rieurement pendant le post-traitement. Les mesures actives et exclues sont clairement s\u00e9par\u00e9es les unes des autres dans la vue d&#8217;ensemble. Cela garantit qu&#8217;un aper\u00e7u est toujours maintenu.   <\/p>\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-2 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"480\" height=\"800\" data-id=\"5483\" src=\"https:\/\/www.nti-audio.com\/wp-content\/uploads\/B2_2024-11-17_SLM_0001_04_screenshot_04.webp\" alt=\"B2 2024 11 17 Slm 0001 04 Capture d'&#xE9;cran\" class=\"wp-image-5483\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"480\" height=\"800\" data-id=\"5484\" src=\"https:\/\/www.nti-audio.com\/wp-content\/uploads\/B2_2024-11-17_SLM_0001_04_screenshot_05.webp\" alt=\"B2 2024 11 17 Slm 0001 04 Capture d'&#xE9;cran\" class=\"wp-image-5484\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"480\" height=\"800\" data-id=\"5486\" src=\"https:\/\/www.nti-audio.com\/wp-content\/uploads\/B2_2024-11-17_SLM_0001_screenshot_06.webp\" alt=\"B2 2024 11 17 Slm 0001 Capture d'&#xE9;cran\" class=\"wp-image-5486\"\/><\/figure>\n<\/figure>\n\n<p>La version V1.42 offre de nombreuses autres nouvelles fonctionnalit\u00e9s.<br\/>Vous trouverez une liste d\u00e9taill\u00e9e <a href=\"https:\/\/my.nti-audio.com\/support\/xl3\/download\/XL3-FW-RevisionHistory.pdf\" target=\"_blank\" rel=\"noopener nofollow\">ici<\/a>.<br\/><a href=\"https:\/\/www.youtube.com\/watch?v=OMSLcZiOZG4\" target=\"_blank\" rel=\"noopener nofollow\">Cette<\/a> courte vid\u00e9o d&#8217;instruction montre comment installer le nouveau firmware.<br\/>Le firmware V1.42 est disponible en t\u00e9l\u00e9chargement <a href=\"https:\/\/my.nti-audio.com\/support\/xl3\/download\/XL3_PKG-1.42.99.8187.zip\" target=\"_blank\" rel=\"noopener nofollow\">ici<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Le firmware V1.42 de l&#8217;Analyseur Acoustique XL3 apporte une interface utilisateur enti\u00e8rement revue qui simplifie consid\u00e9rablement les mesures d&#8217;isolation acoustique. Tous les niveaux de tiers d&#8217;octave dans les pi\u00e8ces d&#8217;\u00e9mission et de r\u00e9ception sont d\u00e9sormais affich\u00e9s sous forme de graphiques lin\u00e9aires. Cela permet un enregistrement visuel intuitif du spectre et permet \u00e9galement d&#8217;afficher simultan\u00e9ment plusieurs [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":8619,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","footnotes":""},"categories":[540],"tags":[],"application-group":[],"product-cats":[],"software-group":[],"class_list":{"0":"post-8618","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-actualites"},"acf":[],"_links":{"self":[{"href":"https:\/\/www.nti-audio.com\/fr\/wp-json\/wp\/v2\/posts\/8618","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.nti-audio.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.nti-audio.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.nti-audio.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.nti-audio.com\/fr\/wp-json\/wp\/v2\/comments?post=8618"}],"version-history":[{"count":0,"href":"https:\/\/www.nti-audio.com\/fr\/wp-json\/wp\/v2\/posts\/8618\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.nti-audio.com\/fr\/wp-json\/wp\/v2\/media\/8619"}],"wp:attachment":[{"href":"https:\/\/www.nti-audio.com\/fr\/wp-json\/wp\/v2\/media?parent=8618"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.nti-audio.com\/fr\/wp-json\/wp\/v2\/categories?post=8618"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.nti-audio.com\/fr\/wp-json\/wp\/v2\/tags?post=8618"},{"taxonomy":"application-group","embeddable":true,"href":"https:\/\/www.nti-audio.com\/fr\/wp-json\/wp\/v2\/application-group?post=8618"},{"taxonomy":"product-cats","embeddable":true,"href":"https:\/\/www.nti-audio.com\/fr\/wp-json\/wp\/v2\/product-cats?post=8618"},{"taxonomy":"software-group","embeddable":true,"href":"https:\/\/www.nti-audio.com\/fr\/wp-json\/wp\/v2\/software-group?post=8618"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}