Room Acoustics Reporter

Room Acoustics Reporter Software

O Room Acoustics Reporter é um software para PC que gera relatórios de medição de tempos de reverberação automaticamente e analisa a resposta em frequência RTA. O software apoia especialistas em acústica na visualização e na avaliação detalhada de dados de medição gravados com o medidor do nível de pressão sonora XL2.

De relance

  • Reverberation Time RT60 according to DIN 18041, ISO 3382, ISO 354, etc.
  • Room acoustic simulation according to Sabine or Eyring
  • Import of user-defined absorber data and tolerances
  • Analysis of Octave or 1/3rd Octave spectra as well as Noise Curves
  • Standard-compliant reporting

Vista geral

O software Room Acoustics Reporter é a ferramenta ideal para a análise de dados e a outorga de relatórios das seguintes medições:

  • Tempo de reverberação RT60
    • Comparação antes / depois de medidas acústicas executadas
    • Adição de materiais absorventes para avaliação
    • Comparação com tolerâncias especificadas em padrões aplicáveis
  • Epectro RTA
    • Média de espectros de ruído gravados em várias posições
    • Cálculo da diferença D dos níveis de pressão sonora entre dois quartos
    • Correção levando em consideração o ruído de fundo
  • Noise Curves, 1/12 Octave and Cinema Meter
    • Verification of measurement results using tolerance data for a pass/fail decision
    • Automatic conversion of 1/12 octave data into 1/3 octave bands
    • Creation of standard-compliant measurement reports

Adição de dados de medição

Arraste os dados gravados de medição diretamente para o software. Todos os dados são atribuídos automaticamente ao conjunto de dados correspondente ao estado antes ou depois de uma medida acústica efetuada na sala.

Adição de dados de medição

Análise dos dados de medição

Avalie os conjuntos de dados individuais para cada medição. O software apresenta o espectro RT60 para cada decaimento do nível de pressão sonora na sala.

Análise dos dados de medição

Resultados

O Room Acoustics Reporter exibe o tempo médio de reverberação em uma tabela e num gráfico padrão de 50 Hz a 10 kHz. Ao mesmo tempo, o tempo médio de reverberação RT60mid na faixa de frequência média é indicado no relatório de medição.

Resultados

 

The Room Acoustics Reporter software can simulate the influence of additional acoustic absorbers installed in the room. Customer-specific absorption coefficients of surface absorbers or objects can be imported into the software. The software calculates the expected new reverberation time and the resulting sound level change in the room. In addition, it presents the A/V ratio and the average sound absorption coefficient in the room. The simulation is performed according to Sabine's formula and the DIN EN 12354-6 standard. For rooms with higher absorption, the simulation can also be performed according to Eyring.

Declarativo

Adicione as descrições do projeto aos dados de medição e imprima o relatório padronizado. O logotipo e a assinatura podem ser desenhados individualmente.

Room Acoustics Reporter Reporting

Frequency Response Spectrum

The Room Acoustics Reporter calculates the average of the imported 1/3 octave spectra and compares the result against a tolerance range. In addition, you can display the level sum or difference of two data sets in the measurement report. The measurement data of the following XL2 functions can be imported: RTA, Noise Curves, 1/12 Octave and Cinema Meter.

Projector PRO XL View

Noise Curves

Noise Curves are used to evaluate background noise in rooms. Load the frequency spectrum, measured with the XL2, into the software, and the measurement report presents a clear comparison of the measurement data within the target range.

Projector PRO XL View

Sound Absorption Coefficient

The ISO 354 and ASTM C423 standards specify a method for determining the sound absorption coefficient of acoustic materials used to clad walls and ceilings, or the equivalent sound absorption area of individual objects such as furniture or people in the room.

Projector PRO XL View

 

The reverberation time is measured with the XL2 Sound Level Meter, with and without absorbers in the room. Based on this data, the Room Acoustics Reporter software calculates the sound absorption coefficient according to the ISO 354, ISO 11654 and ASTM C423 standards. The standardized measurement report also gives the sound absorber class A-E and the single-number values NRC (Noise Reduction Coefficient) and SAA (Sound Absorption Average).

 

I have used the software for a year now and it’s used regularly, not just for reporting reverberation time but also in terms of projecting acoustic solutions. It’s a great software with all the tools and calculations needed.

Michael Miller
Sound InVision, Denmark

Downloads

Como posso importar dados de medição para o software Room Acoustics Reporter?

Room Acoustics Reporter 365

A compra da assinatura do software de acústica da sala permite a importação dos dados de medição de um medidor do nível de pressão sonora XL2 durante um ano. A importação de dados de medição mais antigos também é suportada.

Opção de acústica de salas

Uma licença permanente está disponível como alternativa à assinatura anual. A opção Room Acoustics permite a importação ilimitada de dados de medição para o software de PC "Room Acoustics Reporter". Depois de instalar esta opção no medidor de nível de pressão sonora XL2, os dados de medição gravados podem ser carregados no software.

Instalação em vários PCs

O software pode ser instalado em vários PCs e os dados de medição importados podem ser trocados livremente entre essas instâncias, bem como visualizados e processados posteriormente. Isso possibilita compartilhar os dados de medição dentro de uma equipe ou com o cliente para análises individuais.

Funcionalidade completa

A funcionalidade completa do software pode ser usada com as seguintes opções instaladas no medidor de nível de pressão sonora XL2:

  • Pacote acústico estendido (ativa a funcionalidade para medir o tempo de reverberação RT60 na banda de terceira oitava)
  • Room Acoustics Reporter 365 ou Room Acoustics Option

Configurações

Projector PRO kit

Room Acoustics Reporter 365

Assinatura anual
 

Opção XL2 Room Acoustics

Opção permanentemente instalada no XL2

Obter mais informações