The omnidirectional DS3 Dodecahedron Speaker is a lightweight yet powerful sound source for measurement applications in room and building acoustics. The DS3 is combined with the remote-controlled PA3 Power Amplifier to make up the Dodecahedron Speaker Kit for professionals. The optimized frequency response ensures precise measurements in accordance with the ISO 16283 and ISO 3382 standards.

  • DS3 Dodecahedron Loudspeaker
  • PA3 Power Amplifier
  • Swiss Quality
  • Acoustically flat frequency response
  • Sound power level 120.5 dB
  • Wireless remote control
  • Continuous operation > 1 hour

Attention to Detail

Overview

The Dodecahedron Speaker Kit, comprising of the DS3 Dodecahedron Loudspeaker and the PA3 Power Amplifier, is the measuring equipment designed for professionals for use in their daily measuring tasks in room and building acoustics. Optimized design, combined with unique precision, low weight and flexible operation establish this equipment as a reference in the marketplace.

The DS3 Dodecahedron Loudspeaker is built from twelve specially-developed dynamic drivers that ensure a uniform emission of the acoustic test signal. The PA3 Power Amplifier supplies an equalized pink noise to the DS3. The combination of PA3 and DS3 thus generate an acoustically-flat pink noise under free-field conditions.

Nti Waves

DS3 + PA3

  • DS3 Dodecahedron Speaker

    The DS3 Dodecahedron Speaker is minimized in weight while providing maximum performance and long-term stability. With only 7.5 kg and a typical sound power level of 120.5 dB, the DS3 is most suitable for use on site. The high-performance dynamic driver frames are made of solid aluminum. This provides efficient heat dissipation and hours of level stability. The robust protective grilles prevent damage to the membranes under tough transportation and working conditions. Using the DS3 as a reference sound source provides precise measurement results.

  • PA3 Power Amplifier

    The portable PA3 Power Amplifier contains a DSP-based signal generator with equalizer. In conjunction with the DS3 Dodecahedron Speaker, a pink noise is produced with an acoustically flat frequency response. The equalization ensures that the ISO 16283-1 requirement of ≤ 8 dB difference between contiguous 1/3rd octave bands in the emitted sound is met. A test signal optimized for maximum sound power is available as well as an external audio input socket.

    All operating components are positioned on the sloping sides of the amplifier and illuminated – thus easily recognizable and accessible from a standing position. For low-frequency measurements, an active subwoofer can also be connected. The test signal can be switched on and off from outside the measuring room with the push of a button on the supplied radio remote control.

Recommended power stations

for autonomous operation

ManufacturerTypeOperation Duration* [hours]Voltage [VAC]Capacity [Wh]Weight [kg]Link
GoalzeroYeti 500X1.61205055.9Link
JackeryExplorer 5001.61105126.1Link
Anker535 PowerHouse1.62205127.5Link
EcoflowDeltamini2.912088210.7Link

* with PA3

Configuration

  • DS3 Dodecahedron Speaker Kit

    including

    • PA3 Power Amplifier
      with built-in noise generator
    • DS3 Dodecahedron Speaker
    • Speaker Stand for DS3

Applications

    Speech Intelligibility STIPA

    Test emergency systems and more

    Learn more
    Stipa Dev Img

    Room Acoustics

    Reverberation Time, Speech Intelligibility, Background Noise

    Learn more

    Environmental Monitoring

    Long-term environmental noise monitoring for communities and sites.

    Learn more
    Environmental Noise

    Occupational Noise

    Workplace noise exposure levels and time averages.

    Learn more
    Occupational Noise

Software

  • Data Explorer

    PC software for analysis, reporting and rating level calculations.
    Learn more
  • Sound Insulation Reporter

    PC software for sound insulation measurements, analysis, and standardized reporting.
    Learn more

Trusted by professionals worldwide.

    As a research laboratory invested in supporting communities through real time noise monitoring,  I am very happy to exclusively use NTi instruments. Not only are the robust, easy to use, and provide high quality data, the customer service is outstanding and their team will work with you to find the most cost effective and appropriate solutions needed for problems ranging from easy to difficult.

    User
    Erica D. Walker MSc, ScD, RGSS Assistant Professor of Epidemiology, Brown University School of Public Health
    Bild

    I’ve been using the XL2 for over 15 years for short-term and long-term measurements in all kinds of indoor and outdoor environments all across the country. The meter gets me what I want, when I need it. It’s not only the best value for acoustical measurements, it’s the best tool period. I bet my company and reputation on XL2 results and it has not let me down. You would be crazy not to consider adding NTi instruments to your toolkit.

    User
    Herb Singleton, P.E., INCE Bd. Cert., President, Cross-Spectrum Acoustics
    Bild

    We at Constructure GmbH use two XL3 sound level meters for noise monitoring during demolition work. We are very satisfied with these highly user-friendly instruments, the online monitoring in the MeasurEye Cloud, the good advice and qualified support. Factory calibrations at NTi Audio are also handled very smoothly and without complications.

    User
    Markus Rost, Managing Director, Constructure GmbH
    Bild

Downloads

Trusted by Leading Engineering Teams Worldwide