音響設備

Installed Sound & Evac Test Solution

商業施設、多目的ホール、電話会議システム、講堂、空港、駅、スタジアムで音響設備をインストールする際に、音の明確さと音声の明瞭度は、最も重要な要素です。

At a Glance

  • Commissioning, verification and performance checks
  • Troubleshooting electro-acoustic installations
  • Confirm compliance with system specifications

ファンクション

NTi Audio provides contractors and audio engineers with a comprehensive set of diagnostic and measurements tools. They are tailored for installing, commissioning and troubleshooting sound and audio systems in large commercial spaces so that the PA system produces acceptable levels of intelligibility of speech, the background music is audible and at a pleasant level and, most critically, announcement and emergency messages are loud and clear wherever you may be located in the building.


“What’s that hum? Why is there no sound?”

The Minirator signal generator and XL2 Analyzer are valuable instruments for fast troubleshooting of the audio signal path throughout the installation.
The MR-PRO verifies phantom power supply of microphones, checks XLR cables and measures the load impedance of 70/100 Volt speakers.


Polarity, Delay, Reverberation Time

Use the MR-PRO with the XL2 for an in-depth verification of the polarity - frequency relation for speaker cabinets or other multi-way systems. Configure your delay speakers and analyze the reverberation time RT60 to improve the sound quality and speech intelligibility.


Noise Curves and System Spectral Response

Generate pink noise with the MR-PRO and optimize the frequency response of your system with the XL2 Analyzer. Measure the spectral distribution of the ambient noise with the optional Noise Curve function to verify if the noise rating requirements are met.


Speech Intelligibility

The XL2 measures the intelligibility of speech in an installed environment and generates a measurement report. The measurement set provides you with detailed analysis of sound pressure level, frequency response, reverberation time, ambient noise and distortion, all of which influence speech intelligibility.


Impedance Testing of 70/100V Systems

The Minirator MR-PRO measures the impedance and power rating of distributed speaker systems. Deviations from the expected result identify problems such as bad connections, incorrect tap connections or short circuits. Use the optional 70V/100V Protection Adapter for safe operation.

ワン、ツー、テスト

Talkbox on Stand
You may hear installation engineers repeating the phrase "test, one, two" while setting up microphones. They are not practicing counting; they are checking the frequency response of the microphone. The "uhn" sound of the word "one" produces a low vocal frequency, while the "t" sound in "two" produces a high vocal frequency. (Counting "three, four" adds no more value except perhaps to demonstrate that we installation engineers can, in fact, count past two.)
 
The NTi Audio TalkBox simplifies and improves the setup of microphones by generating a reference human speech signal or other standard audio test signals, so that all frequencies (not just the frequencies produced by "one, two") can be efficiently adjusted by a single person.
 
The TalkBox generates all test signals for professional conference room commissioning. Simply position the TalkBox at each speaking position.

音響設備用Exelセット

Exel Installed Sound Set
セット内容
  • XL2 オーディオ&アコースティックアナライザ
  • STIPA オプション
  • M4261測定用マイクロホン
  • Minirator MR-PRO
  • XL2 用ASDケーブル
  • ケーブルテストプラグ
  • MR-PRO 70/100V プロテクトアダプタ
  • XL2用ACアダプタ
  • MR-PRO用ACアダプタ
  • Exel システムケース

オプション:
 

NTi Audio TalkBox

アコースティックジェネレータ (STIPA リファレンス)
 

スペクトラムリミットオプション

for Noise Curve Measurements

 

お問い合わせ先